Current system
See: Generation for more details of the current generation systems
Modeled wind power
Capital cost (total): $5,128,008
Capital cost (cost per kW): $7,319/kW
Lifetime energy cost savings: $3,856,464
Net lifetime savings: $-1,271,544
Benefit-cost ratio: 0.8
Proposed nameplate capacity: 575 kW
Expected yearly generation: 1,410,360 kWh/year
Estimated wind class: 5
Estimated capacity factor: 0.28
Estimated wind penetration level: 42.09%
Notes: None
source: unknown
Stebbins intertie wind project 0
Capital cost (total): $5,112,249
Capital cost (cost per kW): Value not determined as capital cost of project was known
Lifetime energy cost savings: $2,664,003
Net lifetime savings: $-2,448,246
Benefit-cost ratio: 0.5
Proposed nameplate capacity: 400 kW
Expected yearly generation: 981,120 kWh/year
Estimated wind class: 5
Estimated capacity factor: 0.28
Estimated wind penetration level: 33.04%
Notes: Final design and permitting is under way in a separate grant
source: link